Codesys Sfc Example Official
But then... nothing.
15:47:32.100 - Enter Step 20 (DIP) 15:47:32.105 - Timer started: 45s 15:48:17.200 - Temp fault detected 15:48:17.205 - Exit Step 20 15:48:17.210 - Enter Step 99 (EMERGENCY_RETRACT) 15:48:21.400 - Acid level <5% 15:48:21.405 - Enter Step 0 (IDLE) The coil was perfect. The acid was safe. And Lena finally understood the power of SFC in CODESYS:
She went to the Action Definition for Step 20. Instead of putting Drain_Valve := FALSE in the step's exit action, she created a Global Action called Acid_Safety and set its qualifier to SD (Set Dominant—stays TRUE until explicitly reset).
The problem was chaos. Operators would skip steps, hit "EMERGENCY RESET" mid-dip, or manually open the drain while the coil was submerged. The old ladder logic was a 40-rung monster of interlocking seals that no one understood. codesys sfc example
This is how industrial programmers think. Not just "code that runs"—but .
Lena pointed at the HMI. "No. The SFC saved it. Look—step history."
She added a parallel to the main sequence: But then
Lena shook her head. "No. We need an SFC." She opened CODESYS and created a new POU (Program Organization Unit). She chose Sequential Function Chart (SFC) . No ladder. No structured text loops. Just pure, visual, time-tested sequence logic.
Crane_Up := TRUE; Acid_Drain_Valve := TRUE; // SD qualifier keeps this ON Emergency_Alerter := TRUE; Inside Step 0 's Entry Action:
Lena needed an .
She closed her laptop. "Time to add a heartbeat monitor to the agitator motor," she said. "And maybe buy Dave a coffee." | Concept | In the Story | | :--- | :--- | | Step | Step 20: DIP | | Transition | Condition between steps (e.g., T#45s ) | | Action Qualifier | N (Normal), S (Set), SD (Set Dominant) | | Jump | Jump to Step 99 from a transition | | Parallel Branch | E-Stop logic running alongside main sequence | | Step Entry/Exit Actions | Code that runs when step activates/deactivates | | Implicit Action | Acid_Emergency attached to Step 20 |
[Step 20: DIP] --(45s & no EStop)--> [Step 30: RINSE] | | (EStop_Pressed) v [Step 99: EMERGENCY_RETRACT] --(Acid_Level<5%)--> [Step 0: IDLE] Inside Step 99 's Action:
In CODESYS SFC, she right-clicked Step 20 and selected . She created an Action named Acid_Emergency . She set its qualifier to N (Non-Stored, executes while step is active) and S (Set/Stored for emergency). The acid was safe
The Pickle Paradox System: Industrial Pickling Line (Acid Bath for Steel Coils) Controller: CODESYS SoftPLC v3.5 SP20 Part 1: The Problem Engineer Lena Vasquez stared at the production log. Line 7, the steel coil pickling line, had just scrapped its third $40,000 coil of the week. The sequence: Load coil → Dip in HCl acid → Rinse → Dry → Unload .
"Fix it with a state machine," her manager said.