The arc‑length parameter is updated each load step, ensuring a smooth equilibrium path through post‑peak regimes. | Component | Tool / Library | |-----------|----------------| | FEM core | deal.II (v9.5) | | Linear solver | PETSc (GMRES + ILU) | | Non‑linear solver | Newton‑Raphson with line‑search | | Mesh adaptivity | p4est (parallel refinement) | | Post‑processing | ParaView (VTK output) |
Elements with (\eta_e > \eta_\texttol) are refined (bisected) and coarsening is applied where (\eta_e < 0.1,\eta_\texttol). This strategy concentrates degrees of freedom only where the crack evolves, keeping the global problem size modest. A monolithic coupling (solving (\mathbfu) and (\phi) simultaneously) is possible but computationally expensive. Instead, we adopt the staggered scheme (Miehe et al., 2010) that is unconditionally stable for quasi‑static loading: Working Model 2d Crack-
The phase‑field approach was first introduced by Francfort & Marigo (1998) and later regularised by Bourdin, Francfort & Marigo (2000). Since then, a plethora of works (Miehe et al., 2010; Borden et al., 2012; Wu, 2018) have demonstrated its versatility for quasi‑static, dynamic, and fatigue fracture. However, practical adoption still requires a that guides the user from model formulation to implementation, parameter calibration, and verification. The arc‑length parameter is updated each load step,
The load‑displacement curve obtained with the phase‑field model matches the analytical LEFM prediction for the critical stress intensity factor (K_IC= \sqrtE G_c). The computed (F_c= 4.58) kN is within 2 % of the analytical value. The crack path follows the straight line of the notch, confirming the absence of mesh bias. However, practical adoption still requires a that guides
[ \psi^+(\boldsymbol\varepsilon) ;\rightarrow; H(\mathbfx) . \tag4 ] 3.1. Finite‑Element Discretisation Both fields are approximated using quadratic Lagrange shape functions on an unstructured triangular mesh:
[ \mathbfu^h(\mathbfx) = \sum_i=1^N_n \mathbfN_i(\mathbfx) , \mathbfu i, \qquad \phi^h(\mathbfx) = \sum i=1^N_n N_i(\mathbfx) , \phi_i, \tag5 ]
Figure 1 : Load‑displacement response (phase‑field vs. LEFM). Figure 2 : Phase‑field contour at (F = 0.9F_c) (crack tip radius ≈ 3(\ell)). A DCB specimen (length 0.2 m, thickness 0.01 m) is subjected to a symmetric opening displacement. The energy release rate calculated from the phase‑field solution